Description
Purpose
To test tough gel adhesives to repair meniscus tears under relevant loading conditions and determine if they have adequate biomechanical properties to repair meniscus tears in a bovine cadaveric study.
Methods
Cyclic compression tests on 24 dissected bovine knees were performed. The tough gel adhesive was used either as an adhesive patch or as a coating bonded onto commercially available surgical sutures. Forty-eight menisci were tested in this study; 24 complete radial tears and 24 bucket-handle tears. After preconditioning, the specimens underwent 100 cycles of compression, (800 N/0.5 Hz) on an Instron˝ machine and the size of the gaps measured. One third of the menisci were repaired with pristine sutures, one third with adhesive patches, and one third with sutures coated in adhesive gel. The size of the gaps was compared after 100 and 500 cycles of compression.
Results
The mean gap measured at the tear site without treatment was 6.46 mm (1.41 mm) (mean +-SD) for radial tears and 1.92 mm (0.65 mm) for bucket-handle tears. After treatment and 500 cycles of compression, the mean gap was 1.63 mm (1.41 mm) for pristine sutures, 1.50 mm (1.16 mm) for adhesive sutures and 2.06 mm (1.53 mm) for adhesive gel patches. There was no significant difference between treatments regardless of the type of tear. Also, the gaps for radial tears increased significantly with the number of compression cycles applied (p > 0.001).
Conclusion
From a biomechanical standpoint, the tough adhesive gel patch is as effective as suturing. In addition, it would allow the repair of non-suturable tears and thus broaden the indications for meniscus repair.
Level of evidence
Controlled laboratory study.